Welcome to our NEW website!

X

Model 264

Sewage Pumps // Residential Use // Waste-Mate

Model 264

Submersible sewage/effluent or dewatering pumps.

Features and Benefits

  • Float-operated, submersible (NEMA 6), 2-pole switch
  • Durable, cast iron construction - switch cap, motor and pump housing
  • Engineered plastic base
  • Stainless steel screws, bolts, handle, guard, arm and seal assembly
  • Corrosion-resistant, powder coated epoxy finish
  • Hermetically-sealed, automatic reset thermal overload protection
  • Upper and lower sleeve bearings running in bath of oil
  • Carbon and ceramic shaft seal
  • Passes 2” (50 mm) spherical solids
  • 2” NPT discharge
  • On point: 12-1/2” (31.8 cm)
  • Off point: 4-1/2” (11.4 cm)
  • Simplex and duplex systems available
  • Automatic and non-automatic models available
  • Non-automatic for variable level systems
  • Models available packaged with piggyback variable level float switch

Consult factory for special applications:

  • Electrical alternators for duplex systems available with variable level float switches.
  • Minimum recommended basin size - simplex: 18” x 30” (45.7 x 76.2 cm), duplex: 30” x 36” (76.2 x 91.4 cm)
  • Standard automatic – 4/10 HP, 34.5 lbs.(15.6 kg)
  • High water alarms available
  • Mechanical alternators available for duplex systems
  • The approximate gallons pumped out per cycle for standard models are:

Tank Diameter

Gallons / Liters Pumped

18” (46 cm) simplex

8 gallons / 36 liters

24” (60 cm) simplex

15 gallons / 68 liters

30” (76 cm) duplex

22 gallons / 100 liters

36” (91 cm) duplex

33 gallons / 150 liters

48” (122 cm) duplex

60 gallons / 273 liters

Notes 
The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.

Reserve powered design.

For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.

*May be used in those states where codes do not restrict solids size in effluent systems.

Product Specifications

60hz 50hz
Motor 4/10 HP 0.94 kW
Voltage 115 or 230 V 220 V
Phase 1 Ph 1 Ph
Hertz 60 Hz 50 Hz
RPM 1725 RPM 1400 RPM
Type Permanent split capacitor Permanent split capacitor
Insulation Class B Class B
Amps 4.7 - 9.4 Amps 4.9 A
Operation Automatic or nonautomatic Automatic and nonautomatic
Auto On / Off Points 12-1/2" / 4-1/2 (31.8 cm / 11.4 cm) 31.8 cm / 11.4 cm (12-1/2" / 4-1/2")
Discharge Size 2" NPT 2" NPT (CE models with BSPT)
Solids Handling 2" (50 mm) spherical solids 50 mm (2") spherical solids
Cord Length 10' (3 m) automatic, 15' (5 m) nonauto 5 m (15') standard
Cord Type UL listed, 3-wire cord and plug 16-3 SJEOW
Max Head 18' (5.5 m) 4.3 m (14')
Max Flow Rate 90 GPM (341 LPM) 314 LPM (83 GPM)
Max Operating Temperature 130 °F (54 °C) 130 °F (54 °C)
Cooling Oil filled Oil filled
Motor Protection Auto reset thermal overload Auto reset thermal overload
Cap Cast iron Cast iron
Motor Housing Cast iron Cast iron
Pump Housing Cast iron Cast iron
Base Engineered plastic Engineered plastic
Upper Bearing Sleeve bearing Sleeve bearing
Lower Bearing Sleeve bearing Sleeve bearing
Mechanical Seals Carbon and ceramic Carbon and ceramic
Impeller Type Non-clogging vortex Non-clogging vortex
Impeller Engineered plastic Engineered plastic with metal insert
Hardware Stainless steel Stainless steel
Motor Shaft A151 1215 Steel AISI 1215 or SAE 1045 steel
Gasket Neoprene or Buna-N Neoprene
  • Cert 60Hz
  • Cert Sa
  • Cert Sspma
  • Cert Tough
  • 50Hz
  • Ce

Technical Data

SELECTION GUIDE

  1. Integral float operated mechanical switch, no external control required.
  2. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477.
  3. See FM1228 for correct model of simplex control panel.
  4. See FM0712 for correct model of duplex control panel.

ACCESSORIES

Model Comparison Charts

  • Product Model Comparison Chart: 60hz
    model seal mode volts phase amps hp hz lbs kg
    M264 Single Auto 115 0 9.4 4/10 60 35.5 16
    N264 Single Non 115 0 9.4 4/10 60 34.5 15.6
    BN264 Single Auto 115 0 9.4 4/10 60 40 18
    D264 Single Auto 230 0 4.7 4/10 60 35.5 16
    E264 Single Non 230 0 4.7 4/10 60 34.5 15.6
    BE264 Single Auto 230 0 4.7 4/10 60 40 18
  • Product Model Comparison Chart: 50hz
    model seal mode volts phase amps kw hz lbs kg
    U264 Single Auto 220 0 4.9 0.94 50 36 16
    V264 Single Non 220 0 4.9 0.94 50 36 16

Pump Performance Curves