Latin America / English Change

 

Flow-Mate
140 Series

Effluent or dewatering submersible pump for septic tank, low pressure pipe (LPP) and enhanced flow STEP systems.

 
 
Features andBenefits
ProductSpecifications
TechnicalData
Literature and Documents

  • Durable, cast iron construction
  • Model 140 features a non-clogging, engineered thermoplastic, vortex impeller design and passes 1/2" (13 mm) spherical solids.
  • Model 145 features an engineered thermoplastic, single vane impeller design and passes 3/4" (19 mm) spherical solids.
  • Oil-filled and hermetically-sealed, automatic reset thermal overload protection
  • Available in both single and double shaft seal designs
  • Carbon/ceramic mechanical shaft seals
  • Stainless steel bolts and lifting handle
  • Upper sleeve and lower ball bearing running in bath of oil
  • 1-1/2" NPT vertical discharge
  • Operates at 130° F (54° C) in effluent or dewatering applications
  • BN and BE models include a variable level float switch and 1 ½” x 2” PVC adapter fitting
  • Corrosion-resistant, powder coated epoxy finish

Consult Factory for Special Applications

  • Electrical alternators for duplex systems are available and supplied with an alarm
  • Mechanical alternators for duplex systems are available with or without alarms
  • Control alarm systems are available for 1 Ph pumps used in simplex systems, see FM0732
  • Variable level control switches are available for controlling 1 Ph systems
  • Double piggyback, variable level float switches are available for variable level long cycle controls
  • Sealed Qwik-Box available for outdoor installations, see FM1420
  • Consult factory for applications over 130° F (54° C)
Notes

Note: The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.

 

Reserve Powered Design.

For unusual conditions a reserve safety factor is engineered into the design of every Zoeller® pump.

HERTZ
60 Hz
MOTOR
3/4 - 1 HP
VOLTAGE
115 or 230 V
PHASE
1 Ph
RPM
3450 RPM
TYPE
Permanent split capacitor
INSULATION
Class B
AMPS
6.0 - 13.0 Amps
OPERATION
Automatic or nonautomatic
DISCHARGE SIZE
1-1/2" NPT
SOLIDS HANDLING
1/2" (13 mm), 3/4" (19 mm) spherical solids
CORD LENGTH
20' (6 m) standard
CORD TYPE
UL listed, neoprene cord with molded plug cap and ground wire
MAX HEAD
50' (15.2 m) or 74' (22.6 m)
MAX FLOW RATE
86 GPM (326 LPM) or 61 GPM (232 LPM)
MAX OPERATING TEMP
130° F (54° C)
COOLING
Oil filled
MOTOR PROTECTION
Auto reset thermal overload
CAP
Cast iron
MOTOR HOUSING
Cast iron
PUMP HOUSING
Cast iron
BASE
Cast iron
UPPER BEARING
Sleeve bearing
LOWER BEARING
Ball bearing
MECHANICAL SEALS
Carbon and ceramic
IMPELLER TYPE
Single vane or non-clogging vortex
IMPELLER
Engineered thermoplastic
HARDWARE
Stainless steel
MOTOR SHAFT
JIS S45C steel
GASKET
Neoprene

  • 54
  • 2
  • 8
  • 11
HERTZ
50 Hz
MOTOR
0.9 - 1.0 KW
VOLTAGE
220 V
PHASE
1 Ph
RPM
2800 RPM
TYPE
Permanent split capacitor
INSULATION
Class B
AMPS
4.5 Amps
OPERATION
Nonautomatic
DISCHARGE SIZE
1-1/2" NPT
SOLIDS HANDLING
12 mm (1/2") or 19 mm (3/4") spherical solids
CORD LENGTH
6 m (20') standard
CORD TYPE
SOW/SOOW (CE model H07RN-F)
MAX HEAD
16.8 m (55')
MAX FLOW RATE
16.0 m3/hr (69.7 GPM)
MAX OPERATING TEMP
54°C (130°F)
COOLING
Oil filled
MOTOR PROTECTION
Auto reset thermal overload
CAP
Cast iron
MOTOR HOUSING
Cast iron
PUMP HOUSING
Cast iron
BASE
Cast iron
UPPER BEARING
Sleeve bearing
LOWER BEARING
Ball bearing
MECHANICAL SEALS
Carbon and ceramic
IMPELLER TYPE
Non-clogging vortex or single vane
IMPELLER
Engineered thermoplastic
HARDWARE
Stainless steel
MOTOR SHAFT
AISI 1144 steel
GASKET
Neoprene

  • 14
  • 28
  • 8

Caution

All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).

Selection Guide

  1. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477.
  2. See FM1228 for correct model of simplex control panel.
  3. See FM0712 for correct model of duplex control panel.
  4. See Basins.

Optional Pump Stand P/N 10-2421

Accessories

 

×

 

×